0.635 mm (0.025″) fine-pitch ribbon cable rolls
Order red-edge, 30 AWG ribbon cable by the roll in UL2678 PVC or UL20674 halogen-free TPE. Choose the insulation and conductor count to see the cable width and metres per roll.

Choose the insulation and conductor count
Both materials use 30 AWG stranded conductors (7 × 0.10 mm). For a repeat order, match the insulation on the purchase drawing as well as the cable dimensions.
UL2678 PVC
Drawings 35 and 36 · 22 listed conductor counts
Conductor counts by roll length
Select a conductor count for the width, drawing and row-specific quote.
610 m (2,000 ft) per roll
305 m (1,000 ft) per roll
76.2 m (250 ft) per roll
UL2678 PVC or UL20674 halogen-free TPE?
A 20-conductor cable in either material is 12.7 ± 0.3 mm wide and comes in 76.2 m rolls. If you are replacing an existing cable, the insulation, temperature marking and flame-test requirement on the purchase drawing help distinguish the two.
| Drawing detail | UL2678 PVC | UL20674 TPE |
|---|---|---|
| Insulation | PVC | Halogen-free TPE |
| Temperature shown | 105 °C | −40 to 105 °C |
| Voltage shown | 150 V | 150 V |
| Flame tests listed | VW-1, CSA FT1, FT2 | FT2 |
Compare the original marking and rating blocks on Drawing 35 and Drawing 05. If your BOM specifies a particular halogen, smoke or flame test, include its standard and the evidence your quality team needs with the RFQ.
How many rolls will your cut list use?
Start with the metres per roll for the selected conductor count. Then check how many complete pieces you can cut from each roll. Two jobs that each need 150 m can use a different number of rolls.
60 pieces × 2.5 m
A 76.2 m roll of 20-core cable yields 30 whole pieces before cutting allowances. Two rolls give 60 pieces, with 1.2 m left on each roll.
3 pieces × 50 m
The same roll yields one continuous 50 m piece. This job takes three rolls. Include your longest continuous cut, trimming allowance and any restriction on splices when you request pricing.
Matching a sample or ordering a replacement
Which dimensions should I check on a sample?
Count the conductors, measure the overall ribbon width (W), then check centre-to-centre spacing (PH). For example, on a 20-core sample the centres of the first and last conductors are 19 pitches apart, or about 12.07 mm. The specified overall width is 12.7 ± 0.3 mm. For a connector fit check, the drawings also give an insulated wire OD of 0.68 ± 0.05 mm. See the pitch measurement guide.
Which drawing should I send for a 64-core requirement?
For UL2678 PVC, the 64-core row specifies 40.64 ± 0.4 mm width and 76.2 m per roll. The 0.635 mm entries occupy the upper portion of Drawing 36. For a halogen-free request, send the required width, conductor count and insulation specification for review. Drawing 05 lists TPE sizes through 34 conductors.
What if the roll label is missing?
Send a photo of the cable printing and red edge, the measured width and a conductor count. Add the insulation callout or approved part number from your BOM if available. Both drawings show a red edge, so that detail alone leaves the material unresolved. To look up a different spacing, use the bulk ribbon drawing index.
Request pricing for fine-pitch ribbon cable
Send your required roll quantity or total metres and the delivery destination. For a drawing-specific quote, select a row above to include the cable specification.