Zeakka Electronics
Ribbon cable assembly buyer guides

How to Dimension a Folded Ribbon Cable Between Two PCBs

Give the cable assembler connector datums, fold locations and an installed route that can be checked on the boards.

Give the supplier an installed view and a flat view

The installed view shows where the cable has to go between the two printed circuit boards (PCBs). The flat view locates both terminations and the fold stations along the ribbon. Use matching connector IDs and datums in both views so a reviewer can trace the same piece of cable through the drawings.

Installed side view. Example with two opposite 90° bends and parallel PCB surfaces.
Side profile of a ribbon between PCBs. Exit B is 60 millimetres to the right and 30 millimetres above exit A. Bends F1 and F2 are marked on the rising section.
Flat layout. Free ribbon between the exits, with reference edge C1 and shaded bend regions.
Flat ribbon on its reference face, measured from exit A at zero. Bend centre stations F1 and F2 are at 31.9 and 59.8 millimetres. Exit B is at 85.7 millimetres.

Locate the exits and specify the fold directions

In this example, A and B are where the ribbon centreline in side view leaves the straight constraint of each connector. Exit B is 60 mm to the right and 30 mm higher than A. To reproduce the route on actual boards, locate the connector seating planes and exits from stable PCB surfaces and locating features. Include any sideways offset, connector rotation, local obstacles and space for the full ribbon width.

Viewed as drawn and followed from A to B, the ribbon turns upward at F1, then returns to horizontal at F2. Both bend lines run across the cable width. Use the flat drawing to identify the viewed broad face and the conductor 1 edge. Mark both connector mating faces, pin 1 locations and cable-exit directions. In the example, the exits point towards each other and the cable has no twist. Define the pin map from the chosen connector drawings.

Calculate the free length along the route

In this illustrative geometry, the projected bend corners are 33 mm to the right of A. Each quarter-circle uses a 5 mm radius measured at the assumed cable mid-thickness. These values define the example. Confirm the permissible radius and how it is measured for the chosen cable, bend direction and service conditions before specifying the real bends.

Straight runs
33 − 5 = 28 mm at A, 30 − 2 × 5 = 20 mm between the bends, and 60 − 33 − 5 = 22 mm at B.
Two quarter-circles
Each arc is π × 5 ÷ 2 ≈ 7.85 mm. The total free length is 28 + 20 + 22 + 5π ≈ 85.7 mm.

On the flat view, F1 is halfway through the first arc at 28 + 5π ÷ 4 ≈ 31.9 mm from A. F2 is halfway through the second arc at 28 + 20 + 3 × 5π ÷ 4 ≈ 59.8 mm. These stations identify the centre of each bend region. Show the tangent boundaries or fixture stops when they control the formed shape.

Agree on the dimensions used for manufacture and inspection

The 85.7 mm nominal runs between the selected exit datums. To obtain the cut length, have the supplier account for ribbon inside the terminations, any fold-back, and any required tails or trimming. Agree on the dimension that controls acceptance, its tolerance and the measurement condition. A flat measurement can be specified with the ribbon laid out without stretching. A formed assembly may need both a flat dimension and a fit check in a defined fixture.

State who forms the bends and whether the cable arrives preformed or is routed during installation. For the first sample, check both board position extremes, any restraints and the enclosure lid. The cable should follow the approved route without loading the terminations or exceeding the allowed bend geometry. Record the drawing and fixture revisions with the result.

Record the connector datums in the ribbon cable specification worksheet · Check strain-relief and withdrawal clearance

Review your ribbon cable assembly