Start with one cable and one socket
For an existing PCB, collect the board header and cable socket part numbers separately. Include suffixes for keying, cover and strain relief. Use the socket maker鈥檚 cable specification to select the wire; use its mating drawing to check the header.
Worked example: 0.050-inch cable and a two-row socket
3M鈥檚 3365 series drawing specifies 28 AWG stranded cable with conductors on 0.050-inch (1.27 mm) centres. The 3M 3000 series wiremount socket drawing TS-0718 describes a 0.100 脳 0.100-inch mating grid for 0.050-inch cable. Copy the cable spacing into the cable field and the two mating dimensions into the connector field. Both dimensions belong on this request.
These manufacturer references illustrate how to read the dimensions. To approve a purchase, identify the full cable and socket order codes, the intended conductor count and the cable series allowed for that exact contact. A Zeakka cable with similar dimensions requires its own fit review.
3M cable drawing TS-0080 路 3M socket drawing TS-0718 路 3M cable and connector selection guide
Compare the termination line by line
| Check | Cable evidence | Socket evidence and release question |
|---|---|---|
| Spacing and count | Conductor pitch, number of conductors, overall width and tolerance. | Specified cable pitch, circuit count and cable-entry geometry. Do all conductors register with the intended contacts? |
| Conductor construction | AWG, solid or stranded, strand count and diameter. | Permitted wire range and construction. Is the proposed wire listed or approved for this contact? |
| Insulation profile | Material, insulated conductor dimensions and web profile from the drawing. | Accepted cable series, insulation range or application specification. Ask the manufacturer if the permissible profile is missing. |
| Assembly and mating | Marked reference edge, exit direction and cable routing at each end. | Contact numbering view, key, cover, strain relief and mating header. Mark pin 1 on the end-view drawing. |
Decide what still needs a sample
A published dimensional conflict is a reason to select another candidate. A missing insulation range is an open engineering question: request the application specification or written confirmation. For a new combination, agree on tooling, termination inspection, fit and pin-to-pin and shorts checks with the buyer before authorizing a production lot.
Identify an existing IDC socket 路 Inspect a terminated sample 路 Specify a finished assembly
Keeping your own termination process?
Request the reel against your cable drawing and identify the socket used on your line. For a finished assembly, send both mating references, the connection map, finished length and quantity.