Keep the opening and clamp on the round section
If a round jacket is routed through a grommet and held by a jacket clamp, keep the jacket continuous through both. Put the jacket cut edge beyond the clamp and allow room for the cable to open out before the socket. Use the connector maker’s drawing to locate the cable entry face and check the straight, flat length needed at that entry. Check both ends separately when the enclosure and connector locations differ.
- Panel inner face, datum A
- Jacket clamp
- Jacket cut edge
- Start of fully flat ribbon
- Socket entry face
Start with a traceable cable dimension
On the braided UL20267 construction, the 20P row gives an outer jacket diameter of Ø8.6 ± 1 mm. That makes Ø9.6 mm the upper drawing limit for the jacket in this example. Use the row for your own conductor count and construction. The finished assembly drawing should define the length of the transition and the space it needs in your enclosure. Open Zeakka drawing 03 and see the 20P row.
Work the clearances from the panel face
The example below uses the panel inner face as datum A. The jacket diameter comes from drawing 03. All other dimensions and the connector requirement are hypothetical. The flat width in this example is a finished edge-to-edge envelope.
| Feature | Example dimensions | Fit check |
|---|---|---|
| Panel and grommet | Panel hole Ø12.0 ± 0.2 mm. Installed grommet bore Ø10.2 mm minimum. | The bore leaves 0.6 mm diametral clearance against the Ø9.6 mm maximum jacket. Confirm the grommet fits the panel hole and thickness, and try feeding a sample through it. |
| Jacket cut edge | Clamp occupies 8–16 mm from A at its limits. Cut edge is 24 ± 2 mm from A. | At the earliest cut position, 22 mm from A, 6 mm of jacket remains beyond the clamp. |
| Straight flat run | Fully flat at 44 ± 2 mm from A. Socket entry face at 60 ± 2 mm from A. | The shortest transition is 42 − 26 = 16 mm. The shortest straight flat run is 58 − 46 = 12 mm against a hypothetical 10 mm minimum. |
| Flat ribbon slot | Finished ribbon width 24.8 ± 0.3 mm. Slot width 26.0 ± 0.2 mm. | At the limits, 25.8 − 25.1 = 0.7 mm total width clearance. Check alignment, the thickness clearance and the envelope of any added sleeve. |
Send the installed view and the assembly order
- Mark the panel hole, grommet part number and installed bore. Show which end goes through the opening and when the socket is fitted. If you need a pre-terminated cable, check the largest part that actually passes through, including the cover and strain relief.
- Dimension the cut edge, transition, flat orientation and connector entry from labelled datums. Include the maximum installed width and height, the route, the clamp zone, any boot or sleeve and any movement required for installation or service.
- Add the cable drawing revision, socket and header part numbers, pin 1 orientation, finished length datums, quantity and the proposed first-article fit checks. For a shielded cable, mark the shield cutback and termination separately.
Check connector strain-relief clearance · Specify shield and drain-wire termination