Put each IDC termination inside a usable flat zone
Twist-to-flat ribbon has twisted pairs between sections of parallel, bonded conductors. The flat section presents the conductors to the IDC slots at a fixed pitch. Specify how much usable flat cable each connector needs and where it lands along the ribbon. A roll with the right pair count and conductor pitch can still put a twist transition under the second connector.
Start with the connector and applicable tooling drawings. Mark the contact and cover footprint, cable stop or trim line, and any clamp sections that also need flat cable. Set a minimum usable flat length between the transitions. Then dimension each flat zone relative to an assembly datum, including any branch or pass-through connector. Ask how the supplier identifies the first zone and whether the roll starts at a defined point in the repeat.
Read the repeat and the flat length as separate dimensions
| Cable part | Construction and standard pattern |
|---|---|
| 3M 1700/26 | PVC, 28 AWG stranded with 1.27 mm conductor pitch in the flat zone. In the standard pattern, the drawing gives a 20.0 ± 0.7 in repeat and a 2.0 ± 0.3 in flat section. The same drawing lists suffixes for different flat and repeat lengths. |
| 3M HF100/26TP | Halogen-free polyolefin, 28 AWG stranded with 1.27 mm conductor pitch in the flat zone. The standard repeat is about 500 mm and the flat section about 50 mm. Check TS-2344 for tolerances and possible repeat and flat lengths. |
Read the flat and twisted cross-sections in the 3M 1700 series drawing and suffix table and the 3M HF100 TS-2344 drawing. Check the flat section against the selected IDC slot geometry, cable thickness and insulation limits. Ask for the exact orderable variant, availability, minimum order and lead time for the required pattern. Catalog references establish the published constructions. Zeakka can review sourcing and assembly feasibility against the project drawing.
Worked example for two connectors 300 mm apart
A buyer needs the two IDC press datums 300 mm apart. The tooling and cover require a 16 mm flat footprint centered on each datum. Centering both connectors on adjacent standard 1700/26 flat zones gives about 508 mm between datums. Cutting that cable to the shorter assembly length does not move the second flat zone. Request a pattern that can place both flat zones correctly or review a revised assembly geometry.
In this proposed drawing, the first IDC footprint runs from x = −8 to +8 mm and the second runs from x = 292 to 308 mm. At the minimum flat length and maximum center offset, the closer edge still has 7 mm of flat cable beyond the footprint (18 − 8 − 3 mm). This example assumes the 3 mm allowance covers the total relative offset after cutting and locating the connector. Dimension the cut ends separately and have the supplier confirm that the residual clearance also meets the tooling and cover requirements.
Keep pair identity through both connectors
Mark the reference edge and give a pair-to-pin map for both ends. If pair 1 occupies flat positions 1 and 2 at end A, identify which member carries each polarity and the two receiving contacts at end B. Use the cable drawing to check the order in the flat zones and the connector drawing to check the installed contact order. DC continuity can pass on a split pair if the two correct signals each reach their destination through different physical pairs. Inspect pair membership on the sample. If the interface limits untwisted length, dimension the maximum length between the twist transition and the connected pins, including any breakout. Agree on any impedance, skew or crosstalk verification for the actual interface.
What to send with the RFQ
- Pair count, approved cable part or construction, flat conductor pitch, insulation and shielding requirements, and the edge and pair markings.
- End and inline connector part numbers, complete pair-to-pin schedule, assembly length datums and tolerances, and a dimensioned schedule for the flat zones and clearances to their transitions.
- Sample and production quantities, splice policy for bulk cable, the inspection method for zone placement, and electrical acceptance limits where required.
If quoting finished assemblies, approve a sample for each length and connector layout before repeat orders. If quoting reels for in-house termination, ask for the usable cut yield per roll using the exact zone pattern and planned cuts.
