Can the D-Sub terminate the ribbon directly?
A ribbon cable can go straight into an insulation-displacement (IDC) D-Sub when the connector accepts the cable construction and its IDC slots produce the required wiring. If the equipment needs a different pin sequence, ask whether the ribbon can break out into individual crimp contacts or solder cups at the D-Sub end. The two builds can fit the same equipment port and still have different tooling, labor and inspection requirements.
Identify the equipment-side connector first. Give its part number, contact count, row layout, shell size and mating face. The label “15-pin D-Sub” can describe a standard-density two-row connector or a high-density three-row connector. Compare the standard layout on the TE 1658615-3 IDC plug with the high-density layout on the TE 1-1734530-1 board receptacle. The board receptacle illustrates the mating geometry.
Check the cable entry and the mounting hardware
| Manufacturer part | What to check against the drawing |
|---|---|
| TE 1658615-4 | TE lists a 1.27 mm ribbon centerline, a 2.77 mm mating contact pitch and 4-40 UNC inserts. The customer drawing specifies 26 or 28 AWG solid or stranded round-conductor ribbon. Check the insulation dimensions as well as the wire gauge. |
| Amphenol L17DEFRA09P | The DFR part selector identifies a 3.05 mm clear mounting hole. Compare the flange and fastening hardware with the installed mate. |
| Amphenol L17DEFRBA09P | This DFR plug has an M3 rear insert. Confirm the thread on the equipment and the available screw engagement when the plugs are fully mated. |
Check the exact plug against the TE C-1658615 customer drawing or the Amphenol DFR series datasheet. Confirm conductor count, pitch, strand construction, insulation diameter, and the flat thickness and width accepted by the connector. These catalog references identify components for review. Ask Zeakka to confirm sourcing and tooling for the specified assembly.
Dimension the ribbon exit and clearance with the connector in place. Include any backshell, strain relief, nearby panel edge and bend area. If the assembly needs a shield, show where it bonds to the D-Sub shell and where the shell bonds to the equipment. A metal shell by itself leaves the shield termination unspecified.
Read the pin map in two directions
Number the ribbon conductors from the marked edge and state the viewing direction of both end connectors. The example below uses nine circuits and a standard-density DE-9 plug viewed from the mating side. The wire list is an example of what a buyer would specify. Verify the relationship between the IDC slots and pins on the exact connector or a terminated sample before approving it.
| End A contact | Ribbon conductor | End B D-Sub pin |
|---|---|---|
| A1 | 1 (marked edge) | 1 |
| A2 | 2 | 6 |
| A3 | 3 | 2 |
| A4 | 4 | 7 |
| A5 | 5 | 3 |
| A6 | 6 | 8 |
| A7 | 7 | 4 |
| A8 | 8 | 9 |
| A9 | 9 | 5 |
For example, if the equipment drawing instead calls for A2 to pin 2 and A3 to pin 6 while retaining the other seven connections, the two wires need to exchange destinations. A direct IDC setup that produces the table above cannot make that local swap. A discrete termination gives each wire its own destination, provided the selected contact and backshell can accept the breakout.
What to send with the RFQ
- End A and D-Sub part numbers, installed mates, contact gender, shell drawing, jack hardware, cover and strain relief requirements.
- Cable drawing and complete continuity schedule with view direction, edge mark, any unused contacts and any shield-to-shell connection.
- Finished length with datums and tolerance, exit direction, envelope, prototype and production quantities, and any required test records.
Ask the supplier to identify the proposed termination method and any substitutions in the quote. On the first sample, check every expected path, isolation between independent circuits, mating and screw hold, and clearance with the actual panel in place.
Check ribbon-to-IDC compatibility or review IDC pin-map examples.