Ribbon Cable Assemblies With Different Pin Counts at Each End

Use a six-to-ten-position example to specify the wire map, empty cavities and termination at each end of a custom assembly.

Start with the circuits that must reach the second connector

A six-conductor cable can carry six independent point-to-point connections into a ten-position housing. The extra cavities tell the assembler where contacts may fit. The circuit drawing tells them which contacts to fit and which wires go there. Specify the housing, contact, mating part and populated positions at each end.

Read the two connector faces before reading the wire list

In this drawing example, end A is a six-position IDC socket. The conductors separate near end B, where six individual crimp contacts occupy selected cavities in a ten-position housing. Both views look into the cable connectors from the mating side, with the latch at the top. A wire-entry view would reverse left and right.

End A · 6 positions
Latch ↑
135246
End B · 10 positions
Latch ↑
12345678910
Solid cells contain wired contacts. Dashed cells are empty. The numbering belongs to this example. Use the cavity numbers and viewing direction from the drawings for the parts you order.
Example wire list for the two faces above
Ribbon conductorEnd AEnd B
1A1B1
2A2B2
3A3B4
4A4B6
5A5B8
6A6B10

B3, B5, B7 and B9 have no contacts in this example. If a spare cavity needs a contact with no wire, a seal or a blocking plug, put that item on the drawing and bill of materials. A blank cell in a spreadsheet leaves the assembler to guess.

Choose a termination that can physically make the map

At the crimp end, check the terminal’s allowed conductor size and insulation diameter against the separated ribbon cores. Dimension the breakout from the end of the bonded web to the housing reference. Leave enough free length for the wires to reach their assigned cavities without pulling on the crimps. For two mass-termination ends, ask for the connector manufacturer’s supported cable widths, loading arrangement and tooling before specifying a narrower ribbon in a wider socket.

Give the sample reviewer a pass condition

Send the two part drawings, mating references, wire list, length datums and order quantity with the RFQ. Ask for a sample check against the drawing revision. Each listed A contact should connect to its assigned B contact, the intended independent circuits should remain isolated, and the designated empty cavities should be visibly empty. Where the equipment is available, check mating orientation and breakout reach on the actual boards as well.